The either/or format meant a SubProgramCall with both a non-zero Offset and non-zero Rotation would only show the Offset, hiding the rotation metadata. The data model supports both independently, so the display should too. Also fixes a zero-field leak where the old fallback emitted `G65 P_ R0` for calls with no rotation. Now each field is only shown when non-zero, and `G65 P_` with no arguments is emitted when neither is set. Note: SubProgramCall.ToString is purely a debug/display aid. The Cincinnati post emits sub-calls via the G52 + M98 bracket, not via G65, so this format doesn't correspond to real machine output. Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>