# Lead-in placement at corners
|
|
|
|
Straight (`LineLeadIn`) lead-ins at closed internal contour corners use the
|
|
inward angle bisector instead of the normal of whichever edge was selected.
|
|
With the default 90-degree approach angle, a rectangular cutout therefore gets
|
|
a diagonal lead-in into the scrap, rather than one lying along the other edge.
|
|
This applies to automatic assignment and manual placement. The manual preview
|
|
uses the same Core calculation, including when the lead-in style changes while
|
|
the cursor is stationary.
|
|
|
|
`ContourCuttingStrategy.ComputeLeadInNormal` combines the two adjacent inward
|
|
unit normals. It handles either winding, either selected edge, rotated parts,
|
|
and line/arc junctions using their local normals. Summing vectors avoids angle
|
|
wraparound and edge-length weighting. Open contours, disconnected endpoints,
|
|
zero-length edges, and cusps without a unique bisector retain the entity normal.
|
|
|
|
The configured approach-angle offset is still applied relative to the computed
|
|
normal; 90 degrees follows the bisector. Lead-in length is unchanged. Mid-edge
|
|
points, external contours, circles, curved/composite lead-in styles, and
|
|
lead-outs keep their existing placement rules.
|
|
|
|
This is a local direction correction, not a whole-path clearance guarantee.
|
|
An excessively long lead-in or an approach angle rotated away from the bisector
|
|
can still leave a small cutout. General non-circular containment/length clamping
|
|
and sharp-corner handling for curved/composite lead-ins remain separate work.
|
|
|
|
## Outside perimeter corners
|
|
|
|
A straight (`LineLeadIn`) lead-in at a convex corner of the outside perimeter
|
|
(interior angle under 180 degrees) extends the edge cut first: the pierce sits on
|
|
that edge's line, behind the corner, and the torch travels straight into the corner
|
|
and keeps cutting along the same line. Which of the two edges was picked (auto
|
|
assignment or the manual cursor) does not matter; the cut direction never changes.
|
|
The approach angle is ignored at such a corner.
|
|
|
|
The straight lead is used only while its pierce stays at least
|
|
`CuttingParameters.PierceClearance` (or the [pierce zone](pierce-zone.md) radius, when larger)
|
|
from the contour and the lead crosses the
|
|
contour nowhere but at the corner. Very flat corners (about 165 degrees and over for
|
|
a 0.25 lead with 0.0625 clearance) fall back to the normal lead-in, perpendicular to
|
|
the first-cut edge, so tessellated curves do not get straight leads. Reflex perimeter
|
|
corners (the inside corner of an L) use the notch bisector, like cutout corners.
|
|
|
|
A `LineLeadOut` mirrors this: at a convex perimeter corner it runs straight on past
|
|
the corner along the last-cut edge, with the same clearance fallback to the last-cut
|
|
edge's normal and a bisector at reflex corners. A tabbed perimeter gets no run-out:
|
|
every lead-out style leaves from where the trimmed cut actually ends, on that end's
|
|
normal, so an arc lead-out starts on its own radius and the tab gap stays uncut.
|
|
`ContourCuttingStrategy.ResolveLeadIn`/`ResolveLeadOut` own these rules;
|
|
program generation and the manual preview share them. Other lead-in styles are
|
|
unchanged.
|
|
|
|
## Regression checks
|
|
|
|
Run `dotnet test OpenNest.Tests/OpenNest.Tests.csproj --filter "FullyQualifiedName~CutoutCornerLeadInTests|FullyQualifiedName~PerimeterCornerLeadInTests"`.
|
|
The cutout tests exercise generated part programs, default automatic placement, every
|
|
rectangular corner with both adjoining edges and windings, part rotation, acute
|
|
and obtuse angles, reflex corners, line/arc corners, preview agreement, and
|
|
unchanged/fallback behavior. The perimeter tests cover every square corner under both
|
|
windings and a rotation, auto and manual placement from either edge, preview
|
|
agreement, approach-angle handling, the flat-corner clearance fallback, reflex
|
|
notches, and straight lead-outs.
|
|
|
|
Windows manual check: import a part with small rectangular cutouts and use Plate >
|
|
Assign Lead-ins. Confirm diagonal lead-ins at the cutout corners. Under Plate >
|
|
Place Lead-in, select the part, lock a cutout, and hover a corner: the preview
|
|
should point into the cutout and the committed lead-in should match. Hover a
|
|
mid-edge point and confirm perpendicular placement is unchanged. Windows visual
|
|
interaction is not verified by the Linux cross-build.
|