ajandClaude Fable 5.1 96db154d9e perf(cutting): remember each contour's pierce-zone resolution per preparation
With a pierce diameter set, every internal contour whose configured
pierce is inside the zone is resolved by flattening the cutout, finding
its pole and eroding it, and the search emits a part's whole chain again
on every expansion, so on parts with dozens of such holes almost all of
the planning time went there: three 1,600-motion parts took 41 minutes
and timed out in production. The resolution is a pure function of the
hole, the entry, the configured lead-in, the zone and the turn, so each
preparation now keeps it by contour ordinal and reuses it, unchanged,
across its emissions and copies. The same plate plans in 148 s.

Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
2026-11-02 14:31:45 -05:00
ajandClaude Opus 5.5 4d55e11318 style: use one spelling across the codebase
The repo mixed variants such as center/centre and color/colour, so a
name could be spelled either way and searches missed half the hits.
Standardize on the US spelling, matching .NET's own APIs (Color, Center).

Wire values owned by other systems keep their spelling: the material
ledger's "Cancelled" hold status and GitHub's "cancelled" job status.

No behavior change beyond the spelling of a few status messages.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-30 16:11:30 -04:00
ajandClaude Opus 5.5 2a128c5a11 fix(planning): stop cutout leads at the feature centre line
Small features got leads that ignored their shape: full 0.15 leads at a
shallow angle along letter strokes, stubs at the pierce zone's edge in
round holes that could be pierced in the middle, and a lead aimed at a
letter's far pole that ran longer than configured.

Plan Cutting now limits a lead to the feature's depth at its entry, where
a second wall becomes as near. The pierce-zone fallback goes there first
and otherwise aims beside the entry rather than at the whole cutout's
pole. Pinned contours keep their leads, and wide cutouts are unchanged.

Centred pierces exposed the line/circle tangent test: its absolute
discriminant tolerance called a radial line through a hole under about
0.056 radius tangent, reporting a false contact at the centre. Tangent
now also requires the line to stay at the rim, which keeps true grazes
as they were.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-30 15:31:27 -04:00
ajandClaude Opus 5.5 93cf8007bc feat(cutting): pierce perimeters in open scrap when no lead-in keeps the pierce zone
With a pierce diameter set, a perimeter none of whose configured lead-ins keeps its pierce
clear (a lead shorter than the zone radius, or neighbours closer than it) was only rejected.
Plan Cutting now looks for a pierce in the open scrap around the part instead.

- ScrapPierceSearch (Engine): the window four zone radii around the part, minus every nearby
  part's clean material grown by the zone radius and a margin (ClipperBridge, conservative
  flattening); the clear point nearest each ranked perimeter entry is a candidate. Other
  parts' cutouts count as scrap, the part's own holes do not. With no clear scrap, the
  PolyLabel pole of the free scrap is the best effort, and its shortfall is reported.
- ContourChoice.Pierce / PreparedContours.ScrapPierceEntry: the planner's choice carries the
  pierce; the emitter cuts a straight lead from it to the nearest perimeter point and still
  reads nothing but the contour and the choice.
- Every candidate passes the lead validator like any planner-chosen entry; pinned perimeters
  keep their pins and warn. Without a pierce diameter nothing changes.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-19 01:56:27 -04:00
ajandClaude Opus 5.5 6676f9f6f1 feat(cutting): keep lead-in pierces clear of material with an opt-in pierce diameter
Thick plate pierces leave a crater wider than the kerf. CuttingParameters.PierceDiameter
(Cutting Settings > Pierce Diameter, 0 = off) requires every lead-in pierce to keep half
of it from all part material: its own contour, its holes and every other part.

- LeadPathValidator checks the zone during Plan Cutting candidate checks and final
  replay; fixed emissions warn as usual. No-fit findings explain the zone.
- PierceZoneReview reports Pierce zone warnings before posting for leads from any source.
- Holes whose configured pierce is inside the zone move it toward the hole's PolyLabel
  pole (round holes: the centre), as close to the contour as the zone allows; a hole
  too small for the zone is pierced at its pole and the shortfall is still reported.
- Straight corner leads and round-hole clamping use the larger of PierceClearance and
  the zone radius. The manual lead-in preview shares the Core rules.
- Persisted through the DTO, owned copies and state fingerprint.

Perimeter fallback is not included; see docs/geometry/pierce-zone.md.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-19 01:56:27 -04:00