Fine inscribed flattening still let a native arc cut 6.2e-7 into a 1e-5
clamp unseen: less than one chord's sag, so the layout check, interactive
fill and Check Overlaps all called it clear. Tiny-clamp checks now
circumscribe perimeter arcs and inscribe cutout arcs (lines stay exact), so
the polygons hold every bit of real material. Any real overlap is reported;
the cost is a possible report within the tolerance of an arc, never a false
clear. The analyzer builds the same polygons instead of a second
OverlapMaterial read.
PM 407f5eb7-329f-41e4-947e-64ad52aa4034 (delta review s6-delta-review.md)
The tolerance-free rectangle test was fed approximated material: the layout
check passed it the 1e-4-grid validation outline (a strip of real material
that wholly contains a 1e-5 clamp could vanish), and interactive fill and
the overlap check passed 0.001 inscribed arc chords (a clamp inside a disk
but outside its chords read as clear). All three now flatten the native
contours at a quarter of the clamp's smaller side, lines kept exact, so the
arc-chord sliver can never hold the clamp. Ordinary clamps are unchanged.
PM 407f5eb7-329f-41e4-947e-64ad52aa4034