The File menu ran six output commands together with no separators, and
"Export" / "Export All" didn't say what they exported. Group them by what
they produce:
- Save Copy as .nest File... (was Export .nest...) moves next to Save As,
since it writes the nest file rather than exporting a plate.
- Export Plate... / Export All Plates... (were Export / Export All) get their
own group and the "..." their save dialogs call for.
- Nest Report... / Part Printouts... (were View ...) form a reports group.
- Storage Mode... gets its own separator above Exit.
Export Nest Report... is removed: the report viewer already has Save As
(available even without WebView2), so it was a second path to the same PDF.
Its guard and failure tests now drive the viewer path, and the atomic-write
test calls WriteNestReport directly. The Avalonia prototype's matching
command is renamed too.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Shops used CutSend to get a part printout (the part drawn to fit a Letter
page over a details table) because OpenNest had no way to make one. File >
View Part Printouts prints every part drawing of the nest, and the drawing
list's View Part Printout prints one; both open the report viewer to save
or print.
Cut length and pierce count walk the program as it is cut, so etch marks,
tab spans and display-only moves add neither, a tabbed cutout counts one
pierce per piece, and breakoff and common-line cuts count. The drawing list
item reaches the main window directly so nests made by BOM import get it
too. Rendering shares the nest report's lock, fonts and Latin-1 limit.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
FormStartPosition.CenterParent is not applied to modeless windows, so the
viewer opened wherever Windows placed it. Center it on its owner in OnLoad,
shrunk to fit and kept inside that screen's working area.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Export Nest Report only wrote a file, so checking or printing a report meant
finding it and opening another program. View Nest Report renders the same
snapshot to a private temp folder and opens it in a WebView2 viewer with
Save As and Print; closing the window deletes the temp copy. Export and View
share the capture and write guards.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Desktop test classes each kept identical PumpUntil, Show, Mouse, All,
PressKey, Raise, SetBackingField and Field helpers. They now import
FormTesting and TestReflection; the two Field variants that read a base
type's field or unwrap DrawingLibraryForm keep a one-line wrapper.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Ten desktop test classes drew the same squares and the same 4 x 2
rectangle in private helpers, in two equivalent styles. They now use
TestPrograms.Square, ClockwiseSquare and Rectangle.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
TestAssemblySetup set the unhandled-exception mode and a ThreadException
handler from a module initializer. WinForms stores both per thread
(ThreadContext/NativeWindow thread statics), so they applied only to the
runner thread that loaded the assembly, never to the STA threads the
tests run on. There, an exception escaping a window message or a
BeginInvoke/SynchronizationContext callback still opened a modal
ThreadExceptionDialog in an interactive session, or was silently ignored
otherwise; the handler would also have logged and swallowed it.
Replace the fifteen copied RunSta helpers with StaTestThread.Run, which
selects UnhandledExceptionMode.ThrowException on each STA thread before
it creates a window, so the exception propagates to the test body and
fails the test. Each class keeps its own timeout and message; all
threads are now background threads. Remove TestAssemblySetup.
StaTestThreadTests covers a throwing BeginInvoke callback through
StaTestThread (fails with the original exception) and, as a control,
the default mode on a plain STA thread (the exception goes to the
thread's handler and never reaches the test body). Cross-compiled on
Linux; Windows execution is the windows-desktop CI job.
The new windows-desktop CI job surfaced several tests that had never
actually run on Windows:
- SeparatorPenLifetimeTests expected Control.Disposed to fire only
once; current WinForms re-fires it on every Dispose() call.
- EditNestFocusTraversalTests assumed the Plates tab was selected by
default, which stopped being true once Drawings became the landing
tab; select it explicitly before asserting focus.
- NestReportExportTests asserted an exact plate count that ignored
PlateManager's trailing sentinel plate, and didn't expect the nest
name in the busy-export message.
- AtomicReportFileTests only expected IOException when replacing a
directory target; Windows raises UnauthorizedAccessException instead,
which callers already treat the same way.
Also register a ThreadException handler so an exception inside a
WndProc callback fails the test normally instead of popping a modal
dialog that blocks the desktop.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Capture the report target and reject whole-job nesting, open progress
windows, interactive fill and busy plate actions across every view
sharing the nest; revalidate after the save dialog, capture the snapshot
synchronously on the UI thread and render it through OpenNest.Reporting.
Windows adapter tests cover enablement, guards, cancel, success and a
write failure against an existing destination (compile-only on Linux;
Windows runtime acceptance still owed).