The repo mixed variants such as center/centre and color/colour, so a
name could be spelled either way and searches missed half the hits.
Standardize on the US spelling, matching .NET's own APIs (Color, Center).
Wire values owned by other systems keep their spelling: the material
ledger's "Cancelled" hold status and GitHub's "cancelled" job status.
No behavior change beyond the spelling of a few status messages.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Plan Cutting is now the only automatic lead-in assignment, and parts the
support grid cannot hold level are reported wherever they lack a
steadying tab.
- Remove Assign Lead-ins (plate and nest), LeadInAssigner, the lead-in
tool's Auto-Assign button and the Auto Tab size range; old settings
with autoTab sizes still load
- Manual Place Lead-in tabs the clicked entry when support tabs are on
and the grid cannot hold the part (SupportTabSettings)
- New PartSupport finding: Plan Cutting replay and best-effort plans
warn when a drawing pin, a lead-in that does not fit or no single tab
leaves a part unsteady; the pre-post review checks each placed
program's outside tab gap. These warnings replace the advisory
weak-tab notes; only the inside-corner tab note stays advisory, and
never for a pin
- Pinned perimeters keep their pin but carry the support analysis
- Draw grid points as pixel-snapped squares without anti-aliasing
- Post fixtures build lead-ins through a test-only TestLeadIns helper
- Docs: support tabs, pre-post verification and planner notes
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Assign Lead-ins (LeadInAssigner) now leaves every unlocked part with active
drawing pins unchanged and returns those parts, so it never overwrites a pin
with the plate's settings; the desktop names them ("N parts kept their
drawing lead-ins (plate P: parts ...); use Plan Cutting to apply their
drawing pins."). Parts without pins, with pins switched off, or locked are
assigned or skipped exactly as before.
The pre-post review now covers drawing pins. A part with active pins whose
placed program does not cut each pinned contour exactly as the pin's own
emission (re-emitted with the part's cutting settings and matched motion for
motion) warns "Drawing pins not applied", as do locked lead-ins overriding
pins and a pin that no longer matches the geometry; pins switched off are
not reported. The contours that are cut as pinned join locked programs in
the fixed-lead re-check against every part's clean material, and fixed
leads are now also checked against active clamps (Plan Cutting itself does
not model clamps).
AGENTS.md records the fixed-emission safeguard and the characterization
digests.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>