Automatic cut-offs refused any part reaching past the physical sheet by
more than Tolerance.Epsilon. Imported supplied blanks (panel doors,
remnants) equal their sheet but carry PEP's rounding: a 0.000006 outline
skew plus placements rounded to 0.001 put the never-cut outline 0.00001
to 0.00003 in past the sheet, so Plan Cutting refused every such nest.
A display perimeter may now extend up to DisplayPerimeterSheetAllowance
(0.0001 model units) past the sheet. Nothing cuts it, and a blank that
fills its sheet gets no cut-offs. Everything else on the part keeps the
ordinary tolerance: cuts, leads, scribes and travel, except a rapid that
ends on the outline itself (the move to its first corner, or an applied
program's display tail). A larger overhang is still refused.
With the pre-post risks acknowledged, an unplanned blank reached the
Cincinnati and engraver posts, which created the output file before
refusing: an existing program at that path was emptied and the desktop
had no handler for the refusal. Both posts now check every part before
creating the file, and Post shows the refusal like the multi-file path.
A display tail marker is now honoured only as one marker ending the
part's own program, followed by a rapid and the outline alone. A marker
inside a sub-program or followed by real cuts is refused by posts and by
executed reads, so cuts after it can never be dropped from both
verification and output.
Enclosure was tested at one point per entity, so a round cutout starting
on the blank but running past its edge, or a cutout whose corners all sit
on an L-shaped blank while an edge crosses its notch, reached an
unverified plan that warning acceptance could apply, cutting into or past
the never-cut edge. Every cut is now sampled along its arcs inside the
outline and must not cross or touch it, and the material capture names the
display perimeter when a cut crosses it.
A support bed that cannot hold a blank level and a pierce zone both steer perimeter-led planning paths. A blank has no cut perimeter, so both settings must still plan only its cutouts, with every cut inside them.
Place Lead-in built its contours from cut-layer entities only, so on a
blank the largest cutout looked like the outside and took an external
lead pierced on the blank; committing then regenerated the part with the
outline as a cut perimeter. The legacy whole-part strategy did the same.
Both strategies now refuse a program with a display perimeter and leave
the part unchanged, and Place Lead-in explains that such a part's cutouts
get their leads from Plan Cutting instead of selecting it.
An applied cutting program for a display-perimeter blank held only its
cutouts, so the part shrank to them: a 30 x 20 door reported an 11.5 x 20
extent, overlap and the plate view lost the blank, and running automatic
cut-offs afterwards added lines straight through it.
A complete emission now ends with a display tail: a marker comment, a
rapid to the outline and the outline on the display perimeter layer. The
part keeps the blank's bounds and material, so later cut-offs still have
nothing to cut and the door plans again as before. Nothing executes the
tail: executed reads stop at the marker, so search, replay and the
pre-post review see only the cuts, and cut time, the rapid display and the
cut simulation leave it out. DisplayPerimeterTail.ForPosting gives posts
the program without it and refuses an unplanned display perimeter.
Review found three blanks that slipped past or failed silently. Enclosure
was checked against the outline's bounding box, so a cutout in the notch of
an L-shaped blank reached an unverified plan that warning acceptance could
apply; every cut point is now tested inside the outline itself, and the
material capture names the display perimeter when no ring encloses the
rest. A blank whose only cutouts are tabbed left the search with nothing
to choose and ended without a finding; it is now refused with its reason,
as is a blank with nothing to cut, which used to get only the generic
noncutting message. None of these offers even an unverified plan.
Clean-bounds containment, seam overcut trimming and incremental closure
drift now treat the display perimeter like the other material boundaries.
Some jobs cut only cutouts into a supplied blank, such as instrument holes
in a purchased door that is the whole sheet. Its outline has to be known
to the planner (the blank is material that leads, rapids and cut-offs must
respect) but must never be pierced, led or cut.
A new DisplayPerimeter layer marks that outline. It is material, so
nesting, containment, lead clearance and automatic cut-offs all see the
blank; a door that fills its sheet leaves cut-offs nothing to cut. Cutting
preparation keeps it out of the contours entirely: with no cut perimeter
every contour is a hole with internal leads, and the search, best-effort
and safest-route paths stop offering a perimeter. Replay refuses any run
along the display perimeter and completes once every other ring is cut.
A display perimeter must be one whole closed contour enclosing every other
contour; a mixed ring, one inside another contour, or a second one is
refused with that reason. Saving, drawing and posting it are still to do.