ajandClaude Opus 5.5 93cf8007bc feat(cutting): pierce perimeters in open scrap when no lead-in keeps the pierce zone
With a pierce diameter set, a perimeter none of whose configured lead-ins keeps its pierce
clear (a lead shorter than the zone radius, or neighbours closer than it) was only rejected.
Plan Cutting now looks for a pierce in the open scrap around the part instead.

- ScrapPierceSearch (Engine): the window four zone radii around the part, minus every nearby
  part's clean material grown by the zone radius and a margin (ClipperBridge, conservative
  flattening); the clear point nearest each ranked perimeter entry is a candidate. Other
  parts' cutouts count as scrap, the part's own holes do not. With no clear scrap, the
  PolyLabel pole of the free scrap is the best effort, and its shortfall is reported.
- ContourChoice.Pierce / PreparedContours.ScrapPierceEntry: the planner's choice carries the
  pierce; the emitter cuts a straight lead from it to the nearest perimeter point and still
  reads nothing but the contour and the choice.
- Every candidate passes the lead validator like any planner-chosen entry; pinned perimeters
  keep their pins and warn. Without a pierce diameter nothing changes.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-19 01:56:27 -04:00
ajandClaude Opus 5.5 6676f9f6f1 feat(cutting): keep lead-in pierces clear of material with an opt-in pierce diameter
Thick plate pierces leave a crater wider than the kerf. CuttingParameters.PierceDiameter
(Cutting Settings > Pierce Diameter, 0 = off) requires every lead-in pierce to keep half
of it from all part material: its own contour, its holes and every other part.

- LeadPathValidator checks the zone during Plan Cutting candidate checks and final
  replay; fixed emissions warn as usual. No-fit findings explain the zone.
- PierceZoneReview reports Pierce zone warnings before posting for leads from any source.
- Holes whose configured pierce is inside the zone move it toward the hole's PolyLabel
  pole (round holes: the centre), as close to the contour as the zone allows; a hole
  too small for the zone is pierced at its pole and the shortfall is still reported.
- Straight corner leads and round-hole clamping use the larger of PierceClearance and
  the zone radius. The manual lead-in preview shares the Core rules.
- Persisted through the DTO, owned copies and state fingerprint.

Perimeter fallback is not included; see docs/geometry/pierce-zone.md.