Commit Graph
2 Commits
Author SHA1 Message Date
ajandClaude Opus 5.5 e1ccd69291 fix(cutting): keep configured tab lead-outs and warn; count every tabbed part as steady
5776fa80 dropped a tabbed outside's lead-out when it would reach the lead-in,
which silently changed the user's cutting settings. The emitter now keeps the
lead-out as configured again. Plan Cutting plans strictly first, as before;
only when that is refused because such a lead-out may cut its tab free does it
plan again keeping the lead-outs. Each affected part gets a "Tab lead-out"
issue (new PostVerificationKind.TabLeadOut), is treated as cut free for later
rapids, and the plan is UNVERIFIED, so applying it needs explicit acceptance.
The short reorder pass never settles for such a plan, so a clean route still
wins. Locked, fixed and posted programs keep the incomplete-check finding.

The "no single tab can steady it" support warnings caused more trouble than
they solved, so a tabbed part now counts as steady wherever its tab is: Plan
Cutting and the pre-post review warn only about a part cut with no tab at
all, and a tabbed part stays crossable once cut instead of being avoided as
one that may tip. Entry choice still prefers the steadiest tab point.

The problem-nest corpus is unchanged except N26-2AM, whose baseline is now
BestEffort with 15 tab lead-out warnings.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-16 12:34:34 -05:00
ajandClaude Opus 5.5 8c7dc41ce8 feat(planning): warn about tipping parts and retire legacy lead-in assignment
Plan Cutting is now the only automatic lead-in assignment, and parts the
support grid cannot hold level are reported wherever they lack a
steadying tab.

- Remove Assign Lead-ins (plate and nest), LeadInAssigner, the lead-in
  tool's Auto-Assign button and the Auto Tab size range; old settings
  with autoTab sizes still load
- Manual Place Lead-in tabs the clicked entry when support tabs are on
  and the grid cannot hold the part (SupportTabSettings)
- New PartSupport finding: Plan Cutting replay and best-effort plans
  warn when a drawing pin, a lead-in that does not fit or no single tab
  leaves a part unsteady; the pre-post review checks each placed
  program's outside tab gap. These warnings replace the advisory
  weak-tab notes; only the inside-corner tab note stays advisory, and
  never for a pin
- Pinned perimeters keep their pin but carry the support analysis
- Draw grid points as pixel-snapped squares without anti-aliasing
- Post fixtures build lead-ins through a test-only TestLeadIns helper
- Docs: support tabs, pre-post verification and planner notes

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-10-20 23:54:40 -04:00