Machine Configuration held one lead-in and lead-out per thickness and
applied it to every contour. Each thickness now has Outside Cuts and
Inside Cuts tabs; inside cuts follow the outside leads until "Same as
outside cuts" is cleared, and configurations without inside leads keep
applying one pair to both.
The lead type lists, per-type fields and preview from Cutting Settings
are now a reusable LeadsEditor control that both dialogs use. The
machine tabs hide what the configuration cannot hold: the arc sweep,
the clean-hole kerf (taken from the thickness) and Line + Line.