ajandClaude Opus 5.5 e0bc97a719 fix(cutting): plan support-tabbed perimeters that have a lead-out
Every part the support grid could not hold level got a tabbed perimeter
with the outside lead-out after its tab, and planning refused any lead-out
after its own open cut, so with a lead-out configured no such part could
be planned. Pre-post review already proves such cuts release nothing (the
lead-out stays out of the tab gap); planning now runs the same proof, so
planning and review agree and a lead-out that reaches into the tab is
still refused.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-02 09:33:57 -05:00
..
2026-03-18 16:47:42 -04:00