Place Lead-in built its contours from cut-layer entities only, so on a blank the largest cutout looked like the outside and took an external lead pierced on the blank; committing then regenerated the part with the outline as a cut perimeter. The legacy whole-part strategy did the same. Both strategies now refuse a program with a display perimeter and leave the part unchanged, and Place Lead-in explains that such a part's cutouts get their leads from Plan Cutting instead of selecting it.