N26-2J9 (292 parts on seven stock sizes) needs about 200 s for Auto Nest
on a 4-core test machine, so it failed as Timeout under the shared 120 s
limit although it meets its baseline. An "auto-nest:" line can now say
"limit 300 s": the longer of that and the shared limit applies, so
OPENNEST_PROBLEM_NESTS_TIMEOUT can still raise every limit but never cuts
this one short. Recording a baseline keeps the entry.