Recovery only tried contiguous runs of clamps, so a part with a notch over a middle clamp had all three clamps removed although the two outer ones were enough (D8: 'the fewest clamps that let it fit'). One probe per clamp now finds the clamps every removal must include (a part that cannot fit with only that clamp left needs it off; removal is monotone), and the search tries every set by size, mandatory clamps plus the optional ones nearest the origin first. Full-sheet parts resolve with one probe per clamp. PM 3df03af2-35a6-49c2-9082-fc6208f5b708